{"id":30048,"date":"2026-03-12T13:00:39","date_gmt":"2026-03-12T13:00:39","guid":{"rendered":"https:\/\/academicwritersbay.com\/solutions\/bpm207-cost-management-for-architectural-works-tutor-marked-project-two-2026-suss-singapore\/"},"modified":"2026-03-12T13:00:39","modified_gmt":"2026-03-12T13:00:39","slug":"bpm207-cost-management-for-architectural-works-tutor-marked-project-two-2026-suss-singapore","status":"publish","type":"post","link":"https:\/\/academicwritersbay.com\/solutions\/bpm207-cost-management-for-architectural-works-tutor-marked-project-two-2026-suss-singapore\/","title":{"rendered":"BPM207 Cost Management for Architectural Works Tutor-Marked Project Two 2026 | SUSS, Singapore"},"content":{"rendered":"<p>BPM207 TUTOR-MARKED ASSIGNMENT TWO (TMA02)   This assignment is price 14% of the final ticket for BPM207 Cost Management for Architectural Works. The closing date for this assignment is 16 March 2026, 2355 hrs.  Record to College students:  You are to contain the next particulars in your submission: Direction Code, Title of the TMA, SUSS PI No., Your Title, and Submission Date.  Ask 1  (a) Point out the term \u201cdeemed to be integrated\u201d and its implication when archaic within the Construction Digital Size Usual (CEMS). (5 marks) (b) With the support of diagrams and calculation examples, name and designate the \u201cminimal deductions\u201d rule within the CEMS. (10 marks) (c) Establish the relevant CEMS clauses, designate and illustrate with examples how the \u201cminimal deductions\u201d rule is applied when measuring brick partitions and roof coverings. (10 marks)  Ask 2  Figures Q2.1 and Q2.2 reveals the foremost parts of a built-up flat roof. (a) Define the drawings and put collectively a take-off checklist in conjunction with the unit of size for measuring the built-up flat roof coverings and connected roofing works. Establish also the relevant Size Principles (MR) that needs to be archaic to take-off quantities for the roofing work shown. ( 7 marks) (b) Establish the scope, define the drawings for architectural works and put collectively size tactics to take off quantities for the roof coverings and connected roofing works. ( 8 marks)   Usual Notes for Ask 2:    Cement and sand screed will doubtless be in (1:3) mix laid on roof insulation Roof insulation will doubtless be of polystyrene offers and wrapped both facets with two layers of aluminium foil sissalation 450 Waterproofing membrane will doubtless be in two layers of bituminous felt, total 20 mm thick laid on concrete roof deck. Vertical waterproofing membrane will doubtless be 20 mm thick x 250 mm high in two layers and laid against 175 mm thick parapet wall Concrete roof deck, turf and ceiling finishes are now to not be measured.   Resolve Q2.1: Flat Roof Opinion       Resolve Q2.2: Part Diminutive print  \u00a0      Ask 3  Nearly Figures Q3.1 and Q3.2, name the scope, define and put collectively size map to take off quantities for the next architectural works: (a) Roof coverings in conjunction with underlays and particular tiles . ( 15 marks) (b) Trees rafters, ridge, fascia, ceiling joists and barge boards. (15 marks)   Specification Notes for Ask 3:    Roof tiles will doubtless be 365 x 210 clay interlocking tiles with matching ridge, hip and eave tiles and mounted to 50 x 40 mm bushes battens @ 300 mm c\/c with galvanized nails. Particular tiles will doubtless be required at ridge, verges and eaves of roof. Underlay shall comprise of two layers of bitumen felt total 12 mm thick, 50 mm thick fibre glass roof insulation with double sided sisalation foil 450 and fabric mesh 3325 to the underside of roof overlaying. Pitch of roof is laid at 30 degrees slope. Roof overhang at verge and eaves will doubtless be 300 mm broad from the initiating air face of external wall to fringe of roof overlaying. Roof tiles shall project 75 mm beyond the external face of fascia boards. All roof bushes will doubtless be keruing preserved bushes. Scarfed joints to be offered until in every other case acknowledged. Size of ceiling joists is taken up to the external face of the brick partitions. Wall plates 50 x 150 mm will doubtless be measured up to the inner fringe of gable partitions. Half joints will doubtless be offered. The important thing and final rafters will doubtless be stutter at 50 mm away from the inner face of the gable partitions. Fascia boards will doubtless be butt jointed. All dimensions are in millimeters until in every other case indicated.       Resolve Q3.1: A part of Gable Roof (NTS)        Resolve Q3.2: Opinion of Gable Roof (NTS)    Ask 4  Figures Q4.1 and Q4.2 reveals portion of a ground design of a residential unit. Establish the scope, define the drawings for architectural works and put collectively size tactics to take off quantities in conjunction with deductions the save relevant for the next works: (a) Wall, ground and ceiling finishes to kitchen and loo. (12 marks) (b) Wall, ground and ceiling finishes to dwelling room and bedroom in conjunction with skirting. (18 marks)   Usual Notes for Ask 4:    All brick partitions will doubtless be 200 mm thick. Columns size on design will doubtless be 200 x 200 mm square. Wall finishes for Kitchen and Tub will doubtless be of 300 mm x 300 mm x10 mm homogeneous ceramic tiles laid on 20 mm thick cement and sand (1:3) backing screed. Flooring finishes for Kitchen and Tub will doubtless be of 300 mm x 300 mm x10 mm homogeneous ceramic tiles laid on 40 mm thick cement and sand (1:3) backing screed. No skirting is required for Kitchen and Tub. Internal wall finishes to dwelling room and bedroom will doubtless be in two coats of 15 mm thick cement and sand plaster (1:4) and painted with two undercoats and one finishing coat of emulsion paint. Flooring finishes for dwelling room will doubtless be 600 x 300 x 20 mm thick marble slab bedded and laid on 40 mm thick cement and sand mortar (1:3) backing screed. Skirting to dwelling room will doubtless be marble tiles, 65 mm high x 15 mm thick x 300 mm prolonged and laid against brick wall with 15 mm thick cement &#038; sand backing screed (1:3) mix. Flooring finishes for bedroom will doubtless be 100 mm broad x 10 mm thick veneer bushes strips laid on 40 mm thick cement and sand mortar (1:3) backing screed with approved adhesive. Skirting to bedroom will doubtless be bushes veneer strips, 50 mm high x 10 mm thick and laid against plastered surfaces with approved adhesive. No backing screed is required. All ceiling finishes will doubtless be of one undercoat &#038; two finishing coats of 15 mm thick cement and sand (1:4) plaster and performed with one under coat and two finishing coats of emulsion paint. There are no pretend ceilings.    Doors and window openings:    D1 \u2013 1500 x 2100 mm high D2 \u2013 900 x 2100 mm high W1 \u2013 600 x 600 mm high W2 \u2013 1200 x 1400 mm high W3 \u2013 1800 x 1400 mm high      Resolve Q4.1: Flooring Opinion (NTS)      Resolve Q4.2: Part (NTS)   \u2014- END OF ASSIGNMENT \u2014-         Write My Project      Hire SUSS Project Specialists for BPM207 Cost Management for Architectural Works TMA  Native Singapore Writers Team  100% Plagiarism-Free Essay Highest Pride Price Free Revision On-Time Beginning<\/p>\n","protected":false},"excerpt":{"rendered":"<p>BPM207 TUTOR-MARKED ASSIGNMENT TWO (TMA02) This assignment is price 14% of the final ticket for BPM207 Cost Management for Architectural Works. The closing date for this assignment is 16 March 2026, 2355 hrs. Record to College students: You are to contain the next particulars in your submission: Direction Code, Title of the TMA, SUSS PI [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-30048","post","type-post","status-publish","format-standard","hentry","category-solutions"],"_links":{"self":[{"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/posts\/30048","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/comments?post=30048"}],"version-history":[{"count":0,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/posts\/30048\/revisions"}],"wp:attachment":[{"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/media?parent=30048"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/categories?post=30048"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/tags?post=30048"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}