{"id":30050,"date":"2026-03-12T13:00:37","date_gmt":"2026-03-12T13:00:37","guid":{"rendered":"https:\/\/academicwritersbay.com\/solutions\/bpm207-rate-management-for-architectural-works-tutor-marked-project-two-2026-suss-singapore\/"},"modified":"2026-03-12T13:00:37","modified_gmt":"2026-03-12T13:00:37","slug":"bpm207-rate-management-for-architectural-works-tutor-marked-project-two-2026-suss-singapore","status":"publish","type":"post","link":"https:\/\/academicwritersbay.com\/solutions\/bpm207-rate-management-for-architectural-works-tutor-marked-project-two-2026-suss-singapore\/","title":{"rendered":"BPM207 Rate Management for Architectural Works Tutor-Marked Project Two 2026 | SUSS, Singapore"},"content":{"rendered":"<p>BPM207 TUTOR-MARKED ASSIGNMENT TWO (TMA02)   This assignment is value 14% of the final tag for BPM207 Rate Management for Architectural Works. The closing date for this assignment is 16 March 2026, 2355 hrs.  Give away to Students:  You may also presumably be to incorporate the next particulars on your submission: Route Code, Title of the TMA, SUSS PI No., Your Name, and Submission Date.  Demand 1  (a) Indicate the time period \u201cdeemed to be incorporated\u201d and its implication when feeble in the Construction Electronic Size Fashioned (CEMS). (5 marks) (b) With the assist of diagrams and calculation examples, name and level to the \u201cminimal deductions\u201d rule in the CEMS. (10 marks) (c) Name the relevant CEMS clauses, level to and illustrate with examples how the \u201cminimal deductions\u201d rule is utilized when measuring brick walls and roof coverings. (10 marks)  Demand 2  Figures Q2.1 and Q2.2 reveals the particulars of a built-up flat roof. (a) Elaborate the drawings and put together a steal-off checklist along side the unit of size for measuring the built-up flat roof coverings and linked roofing works. Name furthermore the relevant Size Principles (MR) that must be feeble to steal-off portions for the roofing work shown. ( 7 marks) (b) Name the scope, clarify the drawings for architectural works and apply size suggestions to steal off portions for the roof coverings and linked roofing works. ( 8 marks)   Frequent Notes for Demand 2:    Cement and sand screed can be in (1:3) mix laid on roof insulation Roof insulation can be of polystyrene materials and wrapped all aspects with two layers of aluminium foil sissalation 450 Waterproofing membrane can be in two layers of bituminous felt, general 20 mm thick laid on concrete roof deck. Vertical waterproofing membrane can be 20 mm thick x 250 mm high in two layers and laid in opposition to 175 mm thick parapet wall Concrete roof deck, turf and ceiling finishes are no longer to be measured.   Decide Q2.1: Flat Roof Opinion       Decide Q2.2: Section Small print  \u00a0      Demand 3  Simply about Figures Q3.1 and Q3.2, name the scope, clarify and apply size approach to steal off portions for the next architectural works: (a) Roof coverings along side underlays and particular tiles . ( 15 marks) (b) Trees rafters, ridge, fascia, ceiling joists and barge boards. (15 marks)   Specification Notes for Demand 3:    Roof tiles can be 365 x 210 clay interlocking tiles with matching ridge, hip and eave tiles and fastened to 50 x 40 mm timber battens @ 300 mm c\/c with galvanized nails. Special tiles can be required at ridge, verges and eaves of roof. Underlay shall comprise of two layers of bitumen felt general 12 mm thick, 50 mm thick fibre glass roof insulation with double sided sisalation foil 450 and cloth mesh 3325 to the underside of roof overlaying. Pitch of roof is laid at 30 levels slope. Roof overhang at verge and eaves can be 300 mm huge from the out of doors face of external wall to fringe of roof overlaying. Roof tiles shall mission 75 mm past the external face of fascia boards. All roof timber can be keruing preserved timber. Scarfed joints to be equipped unless in any other case said. Size of ceiling joists is taken up to the external face of the brick walls. Wall plates 50 x 150 mm can be measured up to the interior fringe of gable walls. Half of joints can be equipped. The major and final rafters can be dilemma at 50 mm remote from the interior face of the gable walls. Fascia boards can be butt jointed. All dimensions are in millimeters unless in any other case indicated.       Decide Q3.1: Section of Gable Roof (NTS)        Decide Q3.2: Opinion of Gable Roof (NTS)    Demand 4  Figures Q4.1 and Q4.2 reveals part of a ground realizing of a residential unit. Name the scope, clarify the drawings for architectural works and apply size suggestions to steal off portions along side deductions where acceptable for the next works: (a) Wall, ground and ceiling finishes to kitchen and loo. (12 marks) (b) Wall, ground and ceiling finishes to living room and bedroom along side skirting. (18 marks)   Frequent Notes for Demand 4:    All brick walls can be 200 mm thick. Columns dimension on realizing can be 200 x 200 mm sq.. Wall finishes for Kitchen and Bathtub can be of 300 mm x 300 mm x10 mm homogeneous ceramic tiles laid on 20 mm thick cement and sand (1:3) backing screed. Ground finishes for Kitchen and Bathtub can be of 300 mm x 300 mm x10 mm homogeneous ceramic tiles laid on 40 mm thick cement and sand (1:3) backing screed. No skirting is required for Kitchen and Bathtub. Internal wall finishes to living room and bedroom can be in two coats of 15 mm thick cement and sand plaster (1:4) and painted with two undercoats and one ending coat of emulsion paint. Ground finishes for living room can be 600 x 300 x 20 mm thick marble slab bedded and laid on 40 mm thick cement and sand mortar (1:3) backing screed. Skirting to living room can be marble tiles, 65 mm high x 15 mm thick x 300 mm lengthy and laid in opposition to brick wall with 15 mm thick cement &#038; sand backing screed (1:3) mix. Ground finishes for bedroom can be 100 mm huge x 10 mm thick veneer timber strips laid on 40 mm thick cement and sand mortar (1:3) backing screed with licensed adhesive. Skirting to bedroom can be timber veneer strips, 50 mm high x 10 mm thick and laid in opposition to plastered surfaces with licensed adhesive. No backing screed is required. All ceiling finishes can be of one undercoat &#038; two ending coats of 15 mm thick cement and sand (1:4) plaster and carried out with one below coat and two ending coats of emulsion paint. There don&#8217;t seem to be any wrong ceilings.    Doors and window openings:    D1 \u2013 1500 x 2100 mm high D2 \u2013 900 x 2100 mm high W1 \u2013 600 x 600 mm high W2 \u2013 1200 x 1400 mm high W3 \u2013 1800 x 1400 mm high      Decide Q4.1: Ground Opinion (NTS)      Decide Q4.2: Section (NTS)   \u2014- END OF ASSIGNMENT \u2014-         Write My Project      Rent SUSS Project Experts for BPM207 Rate Management for Architectural Works TMA  Native Singapore Writers Crew  100% Plagiarism-Free Essay Highest Pride Rate Free Revision On-Time Supply<\/p>\n","protected":false},"excerpt":{"rendered":"<p>BPM207 TUTOR-MARKED ASSIGNMENT TWO (TMA02) This assignment is value 14% of the final tag for BPM207 Rate Management for Architectural Works. The closing date for this assignment is 16 March 2026, 2355 hrs. Give away to Students: You may also presumably be to incorporate the next particulars on your submission: Route Code, Title of the [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-30050","post","type-post","status-publish","format-standard","hentry","category-solutions"],"_links":{"self":[{"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/posts\/30050","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/comments?post=30050"}],"version-history":[{"count":0,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/posts\/30050\/revisions"}],"wp:attachment":[{"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/media?parent=30050"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/categories?post=30050"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/academicwritersbay.com\/solutions\/wp-json\/wp\/v2\/tags?post=30050"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}